Athena Power AP-MFATX35 350 W Power Supply Review
Overload Tests
Contents
Below you can see the maximum we could pull from this power supply. We couldn’t pull more than that, as the power supply shut down, showing us that its protections were working fine. At this extreme condition, however, noise level at +5 V and +3.3 V outputs were above the maximum allowed, and efficiency dropped below 80 percent.
| Input | Overload Test |
| +12VA | 12 A (144 W) |
| +12VB | 12 A (144 W) |
| +5 V | 10 A (50 W) |
| +3.3 V | 10 A (33 W) |
| +5VSB | 2 A (10 W) |
| -12 V | 0.5 A (6 W) |
| Total | 377.9 W |
| % Max Load | 108.0% |
| Room Temp. | 41.0° C |
| PSU Temp. | 50.8° C |
| AC Power | 478.5 W |
| Efficiency | 79.0% |
| AC Voltage | 113.7 V |
| Power Factor | 0.994 |