Overload Tests

Below you can see the maximum we could pull from this power supply. The objective of this test is to see if the power supply has its protection circuits working properly. The maximum we could pull from this power supply is listed below. During this test, ripple and noise levels were still low, and voltages were still within their allowed range.

Input Overload Test
+12VA 31 A (372 W)
+12VB 31 A (372 W)
+5 V 18 A (90 W)
+3.3 V 18 A (59.4 W)
+5VSB 3 A (15 W)
-12 V 0.5 A (6 W)
Total 889.4 W
% Max Load 118.6%
Room Temp. 47.4° C
PSU Temp. 52.7° C
AC Power 1,145 W
Efficiency 77.7%
AC Voltage 106.3 V
Power Factor 0.998