FSP Aurum 92+ 650 W Power Supply Review
Voltage Regulation Tests
Contents
The ATX12V specification states that positive voltages must be within 5% of their nominal values, and negative voltages must be within 10% of their nominal values. We consider a power supply as “flawless” if it shows voltages within 3% of its nominal values. In the table below, you can see the power supply voltages during our tests and, in the following table, the deviation, in percentage, of their nominal values.
As you can see, the +3.3 V output was touching the lower limit during test five. The minimum allowed for the +3.3 V output is +3.135 V; however, our equipment doesn’t have a three-digit decimal precision.
| Input | Test 1 | Test 2 | Test 3 | Test 4 | Test 5 |
| +12VA | +12.20 V | +12.12 V | +12.10 V | +12.04 V | +11.98 V |
| +12VB | +12.20 V | +12.11 V | +12.05 V | +11.99 V | +11.97 V |
| +5 V | +5.14 V | +5.13 V | +5.11 V | +5.08 V | +5.06 V |
| +3.3 V | +3.24 V | +3.23 V | +3.21 V | +3.18 V | +3.13 V |
| +5VSB | +5.11 V | +5.09 V | +5.04 V | +5.01 V | +4.96 V |
| -12 V | -12.56 V | -12.61 V | -12.69 V | -12.76 V | -12.83 V |
| Input | Test 1 | Test 2 | Test 3 | Test 4 | Test 5 |
| +12VA | 1.67% | 1.00% | 0.83% | 0.33% | -0.17% |
| +12VB | 1.67% | 0.92% | 0.42% | -0.08% | -0.25% |
| +5 V | 2.80% | 2.60% | 2.20% | 1.60% | 1.20% |
| +3.3 V | -1.82% | -2.12% | -2.73% | -3.64% | -5.15% |
| +5VSB | 2.20% | 1.80% | 0.80% | 0.20% | -0.80% |
| -12 V | 4.67% | 5.08% | 5.75% | 6.33% | 6.92% |