Huntkey Jumper 600B Power Supply Review

Overload Tests

Below you can see the maximum we could pull from this power supply. The objective of this test is to see if the power supply has its protection circuits working properly. This unit passed this test, as we couldn’t pull more than shown in the table below because the power supply would shut down, showing that its protections are present and working fine. During this extreme configuration, voltages were still within three percent of their nominal values and noise and ripple levels at +5 V and +3.3 V outputs were still extremely low, but at +12 V they were above 100 mV.

Input Overload Test
+12VA 28 A (336 W)
+12VB 28 A (336 W)
+5 V 12 A (60 W)
+3.3 V 12 A (39.6 W)
+5VSB 3 A (15 W)
-12 V 0.5 A (6 W)
Total 790.4 W
% Max Load 131.7%
Room Temp. 43.8° C
PSU Temp. 48.8° C
AC Power 1,018 W
Efficiency 77.6%
AC Voltage 109.7 V
Power Factor 0.998