In Win Commander II 850 W Power Supply Review
Overload Tests
Contents
Below, you can see the maximum we could pull from this power supply. We couldn’t pull more than that because the power supply shut down, showing that its protections were working well. During this test noise and ripple levels were still extremely low, however, some voltages were outside the proper range. The +3.3 V output was at +3.00 V, the +5 V output was at +4.68 V, and the +5VSB output was at +4.68 V.
| Input | Overload Test |
| +12VA | 33 A (396 W) |
| +12VB | 33 A (396 W) |
| +5 V | 23 A (115 W) |
| +3.3 V | 23 A (75.9 W) |
| +5VSB | 3 A (15 W) |
| -12 V | 0.5 A (6 W) |
| Total | 985.6 W |
| % Max Load | 116.0% |
| Room Temp. | 43.4° C |
| PSU Temp. | 47.6° C |
| AC Power | 1,251 W |
| Efficiency | 78.8% |
| AC Voltage | 104.9 V |
| Power Factor | 0.999 |