In Win GreenMe 750 W Power Supply Review

Load Tests

We conducted several tests with this power supply, as described in the article, “Hardware Secrets Power Supply Test Methodology.” 

First we tested this power supply with five different load patterns, trying to pull around 20%, 40%, 60%, 80%, and 100% of its labeled maximum capacity (actual percentage used listed under “% Max Load”), watching the behavior of the reviewed unit under each load. In the table below, we list the load patterns we used and the results for each load.

If you add all the powers listed for each test, you may find a different value than what is posted under “To
tal” below. Since each output can have a slight variation (e.g., the +5 V output working at +5.10 V), the actual total amount of power being delivered is slightly different than the calculated value. In the “Total” row, we are using the real amount of power being delivered, as measured by our load tester.

The +12VA and +12VB inputs listed below are the two +12 V independent inputs from our load tester. During this test, the +12VA input was connected to the power supply +12V1 and +12V3 rails, while the +12VB input was connected to the power supply +12V2 rail.

Input Test 1 Test 2 Test 3 Test 4 Test 5
+12VA 5.5 A (66 W) 11 A (132 W) 16.5 A (198 W) 21.5 A (258 W) 27.5 A (330 W)
+12VB 5.5 A (66 W) 11 A (132 W) 16 A (192 W) 21.5 A (258 W) 27.5 A (330 W)
+5 V 1 A (5 W) 2 A (10 W) 4 A (20 W) 6 A (30 W) 8 A (40 W)
+3.3 V 1 A (3.3 W) 2 A (6.6 W) 4 A (13.2 W) 6 A (19.8 W) 8 A (26.4 W)
+5VSB 1 A (5 W) 1.5 A (7.5 W) 2 A (10 W) 2.5 A (12.5 W) 3 A (15 W)
-12 V 0.5 A (6 W) 0.5 A (6 W) 0.5 A (6 W) 0.5 A (6 W) 0.5 A (6 W)
Total 152.9 W 296.4 W 446.9 W 583.7 W 748.8 W
% Max Load 20.4% 39.5% 59.6% 77.8% 99.8%
Room Temp. 45.3° C 45.3° C 48.2° C 44.8° C 45.6° C
PSU Temp. 44.6° C 45.2° C 47.1° C 50.1° C 51.1° C
Voltage Regulation Pass Pass Pass Pass Pass
Ripple and Noise Pass Pass Pass Pass Fail at -12 V
AC Power 176.1 W 338.3 W 519.3 W 691.0 W 914.0 W
Efficiency 86.8% 87.6% 86.1% 84.5% 81.9%
AC Voltage 115.8 V 114.0 V 111.1 V 111.0 V 108.4 V
Power Factor 0.963 0.975 0.985 0.987 0.992
Final Result Pass Pass Pass Pass Pass

On our tests, the In Win GreenMe 750 W presented efficiency between 81.9% and 87.6%, matching the 80 Plus Bronze certification, which promises a minimum efficiency of 82% at light (i.e., 20%) and full loads, and 85% at typical (i.e., 50%) load.

Voltage regulation was excellent, with all voltages closer to their nominal values (3% regulation) during all tests. The only exception was the +5VSB output during test five, which was at +4.80 V, still inside the proper range. The ATX12V specification states that positive voltages must be within 5% of their nominal values, and negative voltages must be within 10% of their nominal values.

Let’s discuss the ripple and noise levels on the next page.