Below you can see the maximum we could pull from this power supply. If we tried to pull more than listed the unit would shut down, which is the desirable behavior. During this test noise and ripple continued to be at very low levels, but the +5 V and +3.3 V outputs dropped below their minimum allowed values (+5 V at +4.70 V and +3.3 V at +3.07 V). Efficiency dropped a lot as well.
| Input | Overload Test |
| +12VA | 19 A (228 W) |
| +12VB | 19 A (228 W) |
| +5V | 24 A (120 W) |
| +3.3 V | 24 A (79.2 W) |
| +5VSB | 3 A (15 W) |
| -12 V | 0.5 A (6 W) |
| Total | 658.8 W |
| % Max Load | 109.8% |
| Room Tem p. |
42.8° C |
| PSU Temp. | 46.2° C |
| AC Power | 874 W |
| Efficiency | 75.4% |
| AC Voltage | 106.1 V |