IN WIN Power Man IP-P600CQ3-2 Power Supply Review

Overload Tests

Below you can see the maximum we could pull from this power supply. If we tried to pull more than listed the unit would shut down, which is the desirable behavior. During this test noise and ripple continued to be at very low levels, but the +5 V and +3.3 V outputs dropped below their minimum allowed values (+5 V at +4.70 V and +3.3 V at +3.07 V). Efficiency dropped a lot as well.

Input Overload Test
+12VA 19 A (228 W)
+12VB 19 A (228 W)
+5V 24 A (120 W)
+3.3 V 24 A (79.2 W)
+5VSB 3 A (15 W)
-12 V 0.5 A (6 W)
Total 658.8 W
% Max Load 109.8%
Room Tem
p.
42.8° C
PSU Temp. 46.2° C
AC Power 874 W
Efficiency 75.4%
AC Voltage 106.1 V
Power Factor 0.998