OCZ ModXStream Pro 500 W Power Supply Review
Overload Tests
Contents
If we tried to pull more power with the unit still hot from our previous tests, the unit would shut down. So we waited until the unit was cold and then we immediately started to increase currents until we could find the maximum amount of power we could pull from it. The results you can see below. If we tried to pull one more amp the unit would shut down.
| Input | Overload Test |
| +12VA | 20 A (240 W) |
| +12VB | 20 A (240 W) |
| +5V | 8 A (40 W) |
| +3.3 V | 8 A (26.4 W) |
| +5VSB | 2.5 A (12.5 W) |
| -12 V | 0.5 A (6 W) |
| Total | 569.8 W |
| % Max Load | 114.0% |
| Room Temp. | 44.5° C |
| PSU Temp. | 46.4° C |
| AC Power | 694.0 W |
| Efficiency | 82.0% |