Seasonic G-360 Power Supply Review
Primary Analysis
Contents
On this page, we will take an in-depth look at the primary stage of the Seasonic G-360. For a better understanding, please read our “Anatomy of Switching Power Supplies” tutorial.
This power supply uses one GBU10JL rectifying bridge, which is attached to an individual heatsink. This bridge supports up to 10 A at 100° C. In theory, you would be able to pull up to 1,150 W from a 115 V power grid. Assuming 80% efficiency, the bridge would allow this unit to deliver up to 1,380 W without burning itself out (or 1,553 W at 90% efficiency). Of course, we are only talking about this particular component. The real limit will depend on all the components combined in this power supply.
The active PFC circuit uses one IPP60R199CP MOSFET, which supports up to 16 A at 25° C or 10 A at 100° C in continuous mode (note the difference temperature makes) or 51 A at 25° C in pulse mode. These transistors present a 199 mΩ maximum resistance when turned on, a characteristic called RDS(on). The lower the number
the better, meaning that the transistor will waste less power, and the power supply will have a higher efficiency.
Figure 12: The active PFC diode and the active PFC transistor
The active PFC circuit is managed by an ICE3PCS01 active PFC controller.
The output of the active PFC circuit is filtered by one 270 µF x 420 V Japanese electrolytic capacitor from Hitachi, labeled at 105° C.
In the switching section, two 18N50 MOSFETs are employed using a resonant configuration. Each transistor supports up to 18 A at 25° C or 11 A at 100° C in continuous mode or up to 72 A at 25° C in pulse mode, with a maximum RDS(on) of 220 mΩ.
Figure 14: One of the switching transistors
The switching transistors are controlled by an ICE2HS01G controller.
Figure 15: Resonant controller (left) and active PFC controller (right)
Let’s now take a look at the secondary of this power supply.