Seasonic Platinum Fanless 520 W Power Supply Review

Overload Tests

Below you can see the maximum we could pull from this power supply. The objective of this test is to see if the power supply has its protection circuits working properly. This unit passed this test, since it shut down when we tried to pull more than what is listed below. During this test, noise and ripple levels were still low, with all outputs still within 3% of their nominal values.

Input Overload Test
+12VA 22 A (264 W)
+12VB 22 A (264 W)
+5 V 12 A (60 W)
+3.3 V 12 A (39.6 W)
+5VSB 3 A (15 W)
-12 V 0.5 A (6 W)
Total 651.4 W
% Max Load 125.3%
Room Temp. 49.4° C
PSU Temp. 56.1° C
AC Power 762.2 W
Efficiency 85.5%
AC Voltage 111.8 V
Power Factor 0.996

Similar Posts

Leave a Reply

Your email address will not be published. Required fields are marked *