Seasonic S12D 750 W Power Supply Review

Overload Tests

Below you can see the maximum we could pull from this power supply with it still working within specs. The idea behind of overload tests is to see if the power supply will burn/explode and see if the protections from the power supply are working correctly. This power supply didn’t burn or explode. Even under this overloading efficiency was above 80%.


Input
Maximum
+12V1 30 A (360 W)
+12V2 30 A (360 W)
+5V 20 A (100 W)
+3.3 V 20 A (66 W)
+5VSB 3 A (15 W)
-12 V 0.5 A (6 W)
Total 905.8 W
% Max Load 120.8%
Room Temp. 47.1° C
PSU Temp. 58.2° C
AC Power 1,126 W
Efficiency 80.4%
AC Voltage 98.2 V
Power Factor 0.992