Seasonic S12II Bronze 430 W Power Supply Review
Ripple and Noise Tests
Contents
Voltages at the power supply outputs must be as “clean” as possible, with no noise or oscillation (also known as “ripple”). The maximum ripple and noise levels allowed are 120 mV for +12 V and -12 V outputs, and 50 mV for +5 V, +3.3 V and +5VSB outputs. All values are peak-to-peak figures. We consider a power supply as being top-notch if it can produce half or less of the maximum allowed ripple and noise levels.
The Seasonic S12II Bronze 430 W provided extremely low ripple and noise levels, making it a “flawless” unit here as well.
| Input | Test 1 | Test 2 | Test 3 | Test 4 | Test 5 |
| +12VA | 12.2 mV | 13.4 mV | 15.6 mV | 17.8 mV | 20.2 mV |
| +12VB | 11.4 mV | 12.2 mV | 14.4 mV | 16.4 mV | 18.6 mV |
| +5 V | 8.2 mV | 8.2 mV | 7.8 mV | 8.2 mV | 9.2 mV |
| +3.3 V | 8.4 mV | 8.2 mV | 8.8 mV | 10.6 mV | 12.2 mV |
| +5VSB | 10.2 mV | 10.8 mV | 10.2 mV | 13.4 mV | 15.0 mV |
| -12 V | 8.2 mV | 8.4 mV | 9.6 mV | 11.8 mV | 13.8 mV |
Below you can see the waveforms of the outputs during test five.
Figure 16: +12VA input from load tester during test five at 431.4 W (20.2 mV)
Figure 17: +12VB input from load tester during test five at 431.4 W (18.6 mV)
Figure 18: +5 V rail during test five at 431.4 W (9.2 mV)
Figure 19: +3.3 V rail during test five at 431.4 W (12.2 mV)