Sentey SDP850-SS Power Supply Review

Overload Tests

Below you can see the maximum we could pull from this power supply. The objective of this test is to see if the power supply has its protection circuits working properly. This unit passed this test, since it shut down when we tried to pull more than what is listed below. During this test, noise and ripple levels were still relatively low and voltages were within 3% of their nominal values, except for the +3.3 V output, which was still inside the allowed range, though.

Input Overload Test
+12VA 33 A (396 W)
+12VB 33 A (396 W)
+5 V 20 A (100 W)
+3.3 V 20 A (66 W)
+5VSB 3 A (15 W)
-12 V 0.5 A (6 W)
Total 970.8 W
% Max Load 114.2%
Room Temp. 48.8° C
PSU Temp. 47.9° C
AC Power 1,227 W
Efficiency 79.1%
AC Voltage 103.5 V
Power Factor 0.995