SilverStone ST45SF-G Power Supply Review

Overload Tests

Below you can see the maximum we could pull from this power supply. The objective of this test is to see if the power supply has its protection circuits working properly. This unit passed this test, since it shut down when we tried to pull more than what is listed below. During this test, noise and ripple
levels at the -12 V output surpassed the maximum allowed, at 142.8 mV, and the +3.3 V output was below the minimum allowed voltage, at +3.12 V.

Input Overload Test
+12VA 20.5 A (246 W)
+12VB 20.5 A (246 W)
+5 V 9 A (45 W)
+3.3 V 9 A (29.7 W)
+5VSB 3 A (15 W)
-12 V 0.5 A (6 W)
Total 578.4 W
% Max Load 128.5%
Room Temp. 40.4° C
PSU Temp. 42.4° C
AC Power 694.0 W
Efficiency 83.3%
AC Voltage 112.0 V
Power Factor 0.991