Zalman ZM770-XT Power Supply Review

Overload Tests

We overloaded Zalman ZM770-XT to the maximum listed in the table below. If we increased one amp on any output noise level at +12 V would increase above 120 mV, making the unit to work outside the correct range. During this overloading the -12 V output was already outside range, with a noise level of 134.4 mV (the maximum allowed is 120 mV). Voltages stayed inside a 3% margin from their nominal values, which is terrific.

Input Maximum
+12V1 30 A (360 W)
+12V2 30 A (360 W)
+5V 15 A (75 W)
+3.3 V 15 A (49.5 W)
+5VSB 3 A (15 W)
-12 V 0.5 A (6 W)
Total 867.4 W
% Max Load 112.6%
Room Temp. 48.9° C
PSU Temp. 58.7° C
AC Power 1,100 W
Efficiency 78.9%
AC Voltage 104.9 V
Power Factor 0.997