Akasa Essential Power 350 W Power Supply Review
Overload Tests
Contents
Below you can see the maximum we could pull from this unit. If we tried to pull one extra amp from any output noise levels would increase too much. During this test noise level at +12 V outputs was touching the allowed limit at 112 mV. During this test the +12VB input from our load tester was at +11.37 V, when the minimum allowed is +11.40 V.
| Input | Overload Test |
| +12V1 | 13 A (156 W) |
| +12V2 | 13 A (156 W) |
| +5V | 10 A (50 W) |
| +3.3 V | 8 A (26.4 W) |
| +5VSB | 2 A (10 W) |
| -12 V | 0.5 A (6 W) |
| Total | 394.5 W |
| % Max Load | 112.7% |
| Room Temp. | 44.4° C |
| PSU Temp. | 50.6° C |
| AC Power | 572.0 W |
| Efficiency | 69.0% |
| AC Voltage | 111.1 V |
| Power Factor | 0.706 |