Akasa Essential Power 350 W Power Supply Review

Overload Tests

Below you can see the maximum we could pull from this unit. If we tried to pull one extra amp from any output noise levels would increase too much. During this test noise level at +12 V outputs was touching the allowed limit at 112 mV. During this test the +12VB input from our load tester was at +11.37 V, when the minimum allowed is +11.40 V.

Input Overload Test
+12V1 13 A (156 W)
+12V2 13 A (156 W)
+5V 10 A (50 W)
+3.3 V 8 A (26.4 W)
+5VSB 2 A (10 W)
-12 V 0.5 A (6 W)
Total 394.5 W
% Max Load 112.7%
Room Temp. 44.4° C
PSU Temp. 50.6° C
AC Power 572.0 W
Efficiency 69.0%
AC Voltage 111.1 V
Power Factor 0.706