Enermax Triathlor FC 650 W Power Supply Review

Ripple and Noise Tests

Voltages at the power supply outputs must be as “clean” as possible, with no noise or oscillation (also known as “ripple”). The maximum ripple and noise levels allowed  are 120 mV for +12 V and -12 V outputs, and 50 mV for +5 V, +3.3 V and +5VSB outputs. All values are peak-to-peak figures. We consider a power supply as being top-notch if it can produce half or less of the maximum allowed ripple and noise levels.

The Enermax Triathlor FC 650 W provided extremely low ripple and noise levels, as you can see below.

Input Test 1 Test 2 Test 3 Test 4 Test 5
+12VA 16.6 mV 19.2 mV 23.6
mV
30.6 mV 41.2 mV
+12VB 16.4 mV 18.6 mV 24.6 mV 30.8 mV 44.0 mV
+5 V 8.8 mV 9.2 mV 9.8 mV 14.6 mV 12.2 mV
+3.3 V 8.8 mV 9.6 mV 11.0 mV 12.8 mV 14.2 mV
+5VSB 13.2 mV 15.6 mV 16.6 mV 17.6 mV 22.0 mV
-12 V 14.2 mV 17.8 mV 21.6 mV 29.4 mV 32.4 mV

Below you can see the waveforms of the outputs during test five.

Enermax TriAthlor FC 650wFigure 25: +12VA input from load tester during test five at 649.4 W (41.2 mV)

Enermax TriAthlor FC 650wFigure 26: +12VB input from load tester during test five at 649.4 W (44.0 mV)

Enermax TriAthlor FC 650wFigure 27: +5V rail during test five at 649.4 W (12.2 mV)

Enermax TriAthlor FC 650wFigure 28: +3.3 V rail during test five at 649.4 W (14.2 mV)

Let’s see if we can pull more than 650 W from this unit.