In Win GreenMe 650 W Power Supply Review

Overload Tests

Below you can see the maximum we could pull from this power supply. The objective of this test is to see if the power supply has its protection circuits working properly. This unit passed this test, since it shut down when we tried to pull more than what is listed below. During this test, the +5 V and -12 V outputs presented voltages outside the tighter 3% regulation we always want to see, at +4.78 V and -12.37 V, but they were still inside the allowed range. Noise and ripple levels were still low (around 58 mV at +12 V).

Input Overload Test
+12VA 28 A (336 W)
+12VB 28 A (336 W)
+5 V 12 A (60 W)
+3.3 V 12 A (39.6 W)
+5VSB 3 A (15 W)
-12 V 0.5 A (6 W)
Total 784.6 W
% Max Load 120.7%
Room Temp. 45.0° C
PSU Temp. 48.4° C
AC Power 999.0 W
Efficiency 78.5%
AC Voltage 107.7 V
Power Factor 0.991