Rosewill FORTRESS-650 Power Supply Review

Overload Tests

Below you can see the maximum we could pull from this power supply. The objective of this test is to see if the power supply has its protection circuits working properly. This unit passed this test, since it shut down when we tried to pull more than what is listed below. During this test, noise levels at +3.3 V and +5VSB were above the maximum allowed, at 57.4 mV and 63.4 mV, respectively. The +3.3 V output was outside the tighter 3% regulation we always want to see, at +3.19 V, but still inside the allowed range.

Room Temp.
Input Overload Test
+12VA 30 A (360 W)
+12VB 30 A (360 W)
+5 V 12 A (60 W)
+3.3 V 12 A (39.6 W)
+5VSB 3 A (15 W)
-12 V 0.5 A (6 W)
Total 837.4 W
% Max Load 128.8%
44.8° C
PSU Temp. 52.2° C
AC Power 1,008 W
Efficiency 83.1%
AC Voltage 106.3 V
Power Factor 0.997