SilverStone Strider Gold Evolution 750 W Power Supply Review

Overload Tests

Below you can see the maximum we could pull from this power supply. We couldn’t pull more, as the power supply would shut down, showing that its protections are present and working fine. During this extreme configuration, noise and ripple levels were still extremely low. The +3.3 V and +5VSB outputs dropped below the minimum allowed, at +3.12 V and +4.73 V, respectively. The +5 V output dropped to +4.82 V, still inside the allowed range.

< td>AC Power
Input Overload Test
+12VA 33 A (396 W)
+12VB 33 A (396 W)
+5 V 20 A (100 W)
+3.3 V 20 A (66 W)
+5VSB 3 A (15 W)
-12 V 0.5 A (6 W)
Total 949.4 W
% Max Load 126.6%
Room Temp. 45.4° C
PSU Temp. 49.8° C
1,161 W
Efficiency 81.8%
AC Voltage 104.2 V
Power Factor 0.987