Ripple and Noise Tests

Voltages at the power supply outputs must be as “clean” as possible, with no noise or oscillation (also known as “ripple”). The maximum ripple and noise levels allowed are 120 mV for +12 V and -12 V outputs, and 50 mV for +5 V, +3.3 V and +5VSB outputs. All values are peak-to-peak figures. We consider a power supply as being top-notch if it can produce half or less of the maximum allowed ripple and noise levels.

The Super Flower Golden King 650 W provided low ripple and noise levels, as you can see in the table below.

Input Test 1 Test 2 Test 3 Test 4 Test 5
+12VA 7.4 mV 12.0 mV 15.2 mV 20.6 mV 37.0 mV
+12VB 8.6 mV 13.4 mV 16.8 mV 23.4 mV 42.6 mV
+5 V 6.0 mV 8.2 mV 9.8 mV 10.8 mV 12.8 mV
+3.3 V 4.2 mV 5.6 mV 6.4 mV 8.6 mV 15.0 mV
+5VSB 5.2 mV 6.6 mV 8.8 mV 10.6 mV 17.6 mV
-12 V 9.4 mV 9.0 mV 10.2 mV 10.2 mV 12.2 mV

Below you can see the waveforms of the outputs during test five.

Super Flower Golden King 750wFigure 20: +12VA input from load tester during test five at 654.4 W (37 mV)

Super Flower Golden King 750wFigure 21: +12VB input from load tester during test five at 654.4 W (42.6 mV)

Super Flower Golden King 750wFigure 22: +5V rail during test five at 654.4 W (12.8 mV)

Super Flower Golden King 750wFigure 23: +3.3 V rail during test five at 654.4 W (15 mV)

Let’s see if we can pull more than 650 W from this unit.