Super Flower Golden King 650 W Power Supply Review

Overload Tests

Below you can see the maximum we could pull from this power supply. The objective of this test is to see if the power supply has its protection circuits working properly. This unit passed this test, since it shut down when we tried to pull more than what is listed below. During this test, noise and ripple levels at the +12 V outputs double, but were still below the maximum allowed. All outputs were still inside 3% of their nominal values, except for the +5VSB output, which was below the minimum allowed at +4.72 V.

Input Overload Test
+12VA 28 A (336 W)
+12VB 28 A (336 W)
+5 V 10 A (50 W)
+3.3 V 10 A (33 W)
+5VSB 3 A (15 W)
-12 V 0.5 A (6 W)
Total 778.4 W
% Max Load 119.8%
Room Temp. 45.4° C
PSU Temp. 50.3° C
AC Power 915 W
Efficiency 85.1%
AC Voltage 107.3 V
Power Factor 0.993