Huntkey Jumper 300G Planet3dnow.de Edition Power Supply Review
Overload Tests
Contents
Below you can see the maximum we could pull from this power supply. We couldn’t pull more than that because the power supply shut down, showing that its protections were working just fine. During this test voltages were still inside the tighter 3% regulation, noise and ripple levels were still low, and efficiency was still very high.
| Input | Overload Test |
| +12VA | 14 A (168 W) |
| +12VB | 14 A (168 W) |
| +5 V | 6 A (30 W) |
| +3.3 V | 6 A (19.8 W) |
| +5VSB | 2 A (10 W) |
| -12 V | 0.5 A (6 W) |
| Total | 401.6 W |
| % Max Load | 133.9% |
| Room Temp. | 44.7° C |
| PSU Temp. | 47.8° C |
| AC Power | 463.3 W |
| Efficiency | 86.7% |
| AC Voltage | 112.9 V |
| Power Factor | 0.987 |