Ripple and Noise Tests

Voltages at the power supply outputs must be as “clean” as possible, with no noise or oscillation (also known as “ripple”). The maximum ripple and noise levels allowed are 120 mV for +12 V and -12 V outputs, and 50 mV for +5 V, +3.3 V and +5VSB outputs. All values are peak-to-peak figures. We consider a power supply as being top-notch if it can produce half or less of the maximum allowed ripple and noise levels.

The 3R System AK6-500M provided very low ripple and noise levels for the +12 V and +5 V outputs, but at the +3.3 V, +5VSB, and -12 V outputs, these levels were too high for us to consider this unit “flawless.” The noise levels were always within the allowed range, though.

Input Test 1 Test 2 Test 3 Test 4 Test 5
+12VA 17.8 mV 25.2 mV 34.6 mV 44.2 mV 48.2 mV
+12VB 13.4 mV 21.6 mV 28.0 mV 35.8 mV 40.0 mV
+5 V 13.2 mV 13.0 mV 15.2 mV 16.8 mV 19.2 mV
+3.3 V 27.2 mV 28.6 mV 31.2 mV 36.2 mV 44.8 mV
+5VSB 27.4 mV 28.6 mV 31.8 mV 35.4 mV 41.4 mV
-12 V 65.6 mV 78.2 mV 94.8 mV 112.6 mV 111.6 mV

Below you can see the waveforms of the outputs during test five.

3R System AK6-500M power supplyFigure 16: +12VA input from load tester during test five at 497.8 W (48.2 mV)

3R System AK6-500M power supplyFigure 17: +12VB input from load tester during test five at 497.8 W (40.0 mV)

3R System AK6-500M power supplyFigure 18: +5V rail during test five at 497.8 W (19.2 mV)

Figure 19: +3.3 V rail during test five at 497.8 W (44.8 mV)